The NIOSH Total Inward Leakage Project

While TIL testing under lab conditions is not expected to reflect expected field performance, it represents a performance criterion that will influence PPE design.

The National Institute for Occupational Safety and Health (NIOSH) conducts a range of efforts in the areas of research, information, and service. The NIOSH program portfolio focuses on relevance, quality, and impact. This is achieved through strong involvement of partners and stakeholders through the entire research continuum (conceiving, planning, conducting, translating, disseminating, and evaluating). The programmatic and support structures provide a foundation for staff to carry out its mission to provide national and world leadership to prevent work-related illnesses and injuries.

The NIOSH program portfolio is organized into eight industry sectors (e.g., mining), 15 cross-sector programs (e.g., personal protective technology), and eight coordinated emphasis areas (e.g., nanotechnology). These programs are centered around adverse health outcomes, statutory programs, and global efforts. The Personal Protective Technology (PPT) Program activities include the technical methods, processes, techniques, tools, and materials that support the development and use of personal protective equipment worn by individuals to reduce effects of their exposure to a hazard.

NIOSH created the National Personal Protective Technology Laboratory (NPPTL) in 2001, when Congress underscored the need for improved personal protective equipment and encouraged research for personal protective technologies.  NPPTL manages the NIOSH PPT Program. The mission of both the PPT program and NPPTL is to prevent work-related injury, illness, and death by advancing the state of knowledge and application of personal protective technologies. The vision is to be the leading provider of quality, relevant, and timely PPT research, training, and evaluation.

Starting the TIL Project
A PPT program project involves establishing total inward leakage (TIL) laboratory test capability and performance requirements for respirator certification.

The inward leakage of a respirator is determined by measuring the concentration of a challenge aerosol outside of the respirator, as well as the concentration within the breathing zone. Respirator fit testing normally considers face seal leakage. Total inward leakage defines a protective level achieved by a respirator when the contributions of all leakage paths are considered.

The TIL is defined as the ratio of the external concentration to the breathing-zone concentration. While the total inward leakage testing performed under laboratory conditions is not expected to reflect expected actual field level PPE performance, it does represent a criterion for performance that will influence PPE design and performance. The project is initially addressing the performance requirement for half-mask respirators, including elastomeric and filtering facepiece styles. Other classes of respirators will be incorporated into the program following completion of the half-mask project.

TIL testing is intended to quantify the ability of respirators to fit individuals having a defined range of facial dimensions and cannot replace individual fit testing to ensure the respirator fits the individual user.

The TIL performance requirements will be based on the performance of the current respirators in the class. The performance requirements will be based on the state-of-the-art respirator performance, accounting for differences between laboratory test conditions and workplace conditions. The TIL test will use a panel of subjects with a range of facial dimensions, and the respirators will be tested for performance to those sizes specified by the respirator manufacturer.

The exercises used to stress the facepiece-to-face seal will be similar to those identified in the OSHA respiratory protection standard.

    

  

This photo sequence shows some of the standard tests designed to stress the seal of the respirator. This one, depicting normal deep breathing, has the subject breathe slowly and deeply without talking while in a normal standing position, taking care not to hyperventilate. Standing in place, the subject slowly turns his/her head from side to side between the extreme positions on each side. The head is held at each extreme momentarily so the subject can inhale at each side. Standing in place, the subject slowly moves his/her head up and down and is instructed to inhale in the up position. The probe in the respirator is used to obtain "in mask" samples for the respirator fit testing equipment to calculate a fit factor. The clear tubing from the respirator fit testing equipment connects into the probe to facilitate sampling and measure the number of particles inside the mask, while the blue tube measures the number of air particles air.

This article originally appeared in the November 2007 issue of Occupational Health & Safety.

Product Showcase

  • Magid® D-ROC® GPD412 21G Ultra-Thin Polyurethane Palm Coated Work Gloves

    Magid’s 21G line is more than just a 21-gauge glove, it’s a revolutionary knitting technology paired with an advanced selection of innovative fibers to create the ultimate in lightweight cut protection. The latest offering in our 21G line provides ANSI A4 cut resistance with unparalleled dexterity and extreme comfort that no other 21-gauge glove on the market can offer! 3

  • Preventative Heat Safety

    Dehydration and heat exposure impair physical and cognitive performance. Proper hydration boosts heat stress resilience, but hydration needs are highly individualized and hard to predict across a workforce. Connected Hydration® empowers industrial athletes to stay safe through behavioral interventions, informed by sports science, and equips safety teams with critical insights to anticipate high-risk situations and adapt to evolving environmental factors. Curious about applying the latest in sports science based hydration strategies for industrial athletes? Stop by booth #1112 at AIHA or schedule a free demo today at https://epcr.cc/demo. 3

  • HAZ LO HEADLAMPS

    With alkaline or rechargeable options, these safety rated, Class 1, Div. 1 Headlamps provide long runtime with both spot and flood options in the same light. Work safely and avoid trip hazards with flexible hands-free lighting from Streamlight. 3

Featured

Webinars